IT Parks & Data Centers

Cooling water optimised. Uptime protected. Power consumption minimised.

Data centres run hot. Cooling towers and chiller systems that keep servers online require precisely treated water — or face corrosion, scaling, and Legionella that shuts down racks, not just pumps.

Industry Challenges

What makes it parks & data centers water treatment complex.

Every industry has unique water treatment requirements. Understanding these sector-specific challenges is the starting point for every NWPL project.

Cooling tower water with high TDS (cycles of concentration >5) causes aggressive scaling on heat exchanger surfaces, reducing thermal efficiency and forcing expensive descaling shutdowns.

Legionella in cooling towers is a severe liability for data centre operators — OSHA and ASHRAE 188 require active risk management programmes, not just quarterly testing.

Ultra-pure water for humidification systems must have conductivity <10 µS/cm to prevent white dust contamination on server hardware.

Data centres in water-stressed regions face municipal supply restrictions — on-site STP reuse for cooling tower makeup is increasingly mandatory.

Compact footprint is critical: data centre plant rooms have no spare space for oversized water treatment equipment.

Compliance Requirements

Data centre water compliance spans cooling, fire, and sanitation systems.

NWPL systems are designed to meet every applicable standard for your sector — from the day of commissioning.

ASHRAE 188-2018

Minimum requirements for Legionella Risk Management Programme (WRMP) in buildings

ASHRAE Guideline 12

Minimising the risk of Legionellosis associated with building water systems

BSRIA BG 50

Water treatment for closed heating and cooling systems

CPCB OCEMS Guidelines

Online effluent monitoring for all designated industries including large commercial complexes

ECBC 2017 (BEE)

Energy Conservation Building Code — water efficiency requirements for data centres

Featured Projects

Proven in it parks & data centers.

Hyperscale Data Centre WTP — 2 MLD, Pune
2,000 KLD

Hyperscale Data Centre WTP — 2 MLD, Pune

RO + softening system for cooling tower makeup. Cycles of concentration increased from 3 to 6.5, reducing makeup water consumption 50%. Blowdown treatment enables 85% reuse.

IT Park STP + Reuse — 150 KLD, Hyderabad
150 KLD

IT Park STP + Reuse — 150 KLD, Hyderabad

MBR STP in basement plant room. 120 KLD recycled daily for cooling tower and landscape. ₹36 lakh/year savings in municipal water charges. HMDA OC clearance obtained.