IT Parks & Data Centers
Cooling water optimised. Uptime protected. Power consumption minimised.
Data centres run hot. Cooling towers and chiller systems that keep servers online require precisely treated water — or face corrosion, scaling, and Legionella that shuts down racks, not just pumps.
Industry Challenges
What makes it parks & data centers water treatment complex.
Every industry has unique water treatment requirements. Understanding these sector-specific challenges is the starting point for every NWPL project.
Cooling tower water with high TDS (cycles of concentration >5) causes aggressive scaling on heat exchanger surfaces, reducing thermal efficiency and forcing expensive descaling shutdowns.
Legionella in cooling towers is a severe liability for data centre operators — OSHA and ASHRAE 188 require active risk management programmes, not just quarterly testing.
Ultra-pure water for humidification systems must have conductivity <10 µS/cm to prevent white dust contamination on server hardware.
Data centres in water-stressed regions face municipal supply restrictions — on-site STP reuse for cooling tower makeup is increasingly mandatory.
Compact footprint is critical: data centre plant rooms have no spare space for oversized water treatment equipment.
Our Solutions for IT Parks & Data Centers
Technology matched to your site.
Compliance Requirements
Data centre water compliance spans cooling, fire, and sanitation systems.
NWPL systems are designed to meet every applicable standard for your sector — from the day of commissioning.
ASHRAE 188-2018
Minimum requirements for Legionella Risk Management Programme (WRMP) in buildings
ASHRAE Guideline 12
Minimising the risk of Legionellosis associated with building water systems
BSRIA BG 50
Water treatment for closed heating and cooling systems
CPCB OCEMS Guidelines
Online effluent monitoring for all designated industries including large commercial complexes
ECBC 2017 (BEE)
Energy Conservation Building Code — water efficiency requirements for data centres
Featured Projects
Proven in it parks & data centers.

Hyperscale Data Centre WTP — 2 MLD, Pune
RO + softening system for cooling tower makeup. Cycles of concentration increased from 3 to 6.5, reducing makeup water consumption 50%. Blowdown treatment enables 85% reuse.

IT Park STP + Reuse — 150 KLD, Hyderabad
MBR STP in basement plant room. 120 KLD recycled daily for cooling tower and landscape. ₹36 lakh/year savings in municipal water charges. HMDA OC clearance obtained.
Get a Data Centre Water Proposal
Every site is different. Every system NWPL designs is different. Tell us your constraints — we'll handle the engineering.